Measure Reference Manual

Recovery
Correct the syntax according to HELP or the syntax in this manual.
For command syntax descriptions, see Chapter 2: MEASCOM Commands (page 35). For
descriptions of syntax for identifying entities to be measured, see Chapter 3: Entities and Counters
(page 136).
MEAS 3056
Subsystem error; please report to Tandem Computers Incorporated. Trap
%n, CS = %n, P = %nnnnn, E = %nnnnn, L = %nnnnn, S = %nnnnn.
Cause
A trap was encountered by MEASCOM.
Effect
The requested operation is ignored.
Recovery
Retain a copy of the information provided in the error message and contact your HP
representative.
MEAS 3057
Ambiguous DELETE command; specify which occurrence to delete.
Cause
A DELETE PLOT was requested where the counter name entered occurs more than once in the
plot definition.
Effect
The requested operation is ignored.
Recovery
Repeat the command and either add the plot character to indicate a particular occurrence or
an asterisk (*) to indicate all occurrences.
MEAS 3058
Expecting a valid process or file name.
Cause
MEASCOM was expecting either a valid process name (for example, $XMM) or a valid file
name (for example, $disk.subvol.file, or $disk.subvol.*).
Effect
The requested operation is ignored.
Recovery
Reissue the request with a valid process or file name.
MEAS 3059
Only an individual file can be specified; replace *'s.
Cause
A single file name was not entered for the command.
Effect
The requested operation is ignored.
Recovery
Replace the wild-card character (*) with a specific file name.
MEAS 3060
Expecting a disk file name; ensure filename is a valid disk file name.
503