Measure Reference Manual

MEAS 3070
Both FOR and TO have been specified; delete one and reissue command.
Cause
Both the FOR and TO option were specified in the same command. These options are mutually
exclusive.
Effect
The requested operation is ignored.
Recovery
Delete one of the options and repeat the command.
MEAS 3071
item-name not found; check the spelling and/or the appropriate entity
report.
Cause
The plot counter name entered was not found.
Effect
The requested operation is ignored.
Recovery
Check the spelling and verify, using the appropriate report, that the name entered is a valid item
name. Legacy style report items that are no longer present in the equivalent ZMS style report
can only be plotted in the legacy style interface. And ZMS style report items that are not present
in the equivalent legacy style report can only be plotted in the ZMS style interface.
MEAS 3072
Measurement not active; unable to perform request.
Cause
An attempt was made to issue a command that is valid only when the measurement is currently
active.
Effect
The requested operation is ignored.
Recovery
Informative message only; no corrective action is needed.
MEAS 3073
A remote filename is not allowed when dealing with DISCOPENs or
DISKFILEs.
Cause
The file name entered or expanded (using the current SYSTEM) for a DISCOPEN or DISKFILE
command was for a remote file.
Effect
The requested operation is ignored.
Recovery
DISCOPENs and DISKFILEs are always local. For DISCOPENs, a remote opener can be specified
after the file name (for example, $a.b.c (\sys)). For DISKFILE, no opener information is associated
with the entity, so using a remote opener is not allowed.
MEAS 3074
Plot list is full; must DELETE an item before ADD.