Measure Reference Manual

Cause
You are using a G-series RVU, but the version of the data file precedes F40.00.
Effect
The command is not executed.
Recovery
To analyze a pre-F40.00 data file, use a pre-F40.00 version of MEASCOM that matches the
version of the data file as well as the appropriate MEASFH.
MEAS 3113
Unable to open data file.
Cause
MEASFH was unable to open the data file because there was too much data for the system to
handle (file-system error 21).
Effect
The command is not executed.
Recovery
Retry the command.
MEAS 3114
A journal segment is required but not available for request.
Cause
A command was entered for a data file that was not collected on the current node, and for which
no journal segment is currently available.
Effect
The command is not executed.
Recovery
If the translation desired is NOT from the added data file, then DELETE the measurement and
reissue the command so that the translation is done from the current system. If translation is
desired for data collected on another node, specify the OSS and/or SQL option when starting
the measurement.
MEAS 3115
PAGESIZE must be specified in the range of 6 and 128 inclusive.
Cause
An invalid PAGESIZE setting was specified.
Effect
The requested operation is aborted.
Recovery
Specify a value from 6 through 128 inclusive.
MEAS 3116
Unable to translate OSS file pathname.
Cause
The requested translation was not found in the OSS name space or in the current OSS journal
segment.
Effect
The command is not executed.
514 Error Messages