Measure Reference Manual

Effect
The requested operation aborts.
Recovery
Verify that the Measure subsystem is not running prior to calling MEASMONCONTROL with a
start subsystem request.
3219
(ERR^NOMEASMON)
Cause
The Measure subsystem was stopped.
Effect
The requested operation aborts.
Recovery
Verify that the Measure subsystem is running prior to calling this procedure.
3220
(ERR^UDCNOTPRESENT)
Cause
A user-defined counter was not installed and cannot be bumped.
Effect
The requested operation aborts.
Recovery
Prior to this call, configure a measurement that includes the user-defined counters to be bumped.
3221
(ERR^UDCBADBUMP)
Cause
An invalid BUMPTYPE was used for a user-defined counter.
Effect
The requested operation aborts.
Recovery
Check and correct the value of the BUMPTYPE parameter.
3222
(ERR^UDCBADINDEX)
Cause
An invalid INDEX was used for a user-defined counter.
Effect
The requested operation aborts.
Recovery
Check and correct the value of the INDEX parameter.
3223
(ERR^INVALIDENTITY)
Cause
A new or invalid entity type was supplied.
522 Error Codes