Measure Reference Manual

Recovery
Try reducing the number of items to be LISTed by requesting specific items rather than using the
asterisk (*) to list all items. For the PROCESSH entity, try specifying if code-range > 0 in
the LIST command.
3258
(ERR^CSEGOVERFLOW)
Cause
MEASFH's external counter record segment overflowed.
Effect
The requested operation aborts.
Recovery
Try reducing the number of items to be LISTed by requesting specific items rather than using the
asterisk (*) to list all items. For the PROCESSH entity, try specifying if code-range > 0 in
the LIST command.
3259
(ERR^MEASNOTDONE)
Cause
The measurement was not complete.
Effect
The requested operation aborts.
Recovery
Stop the measurement and retry the operation.
3260
(ERR^NOOPEN)
Cause
The data file was not open.
Effect
The requested operation aborts.
Recovery
Call MEASOPEN for the data file and retry the operation that failed.
3261
(ERR^INTTOOSMALL)
Cause
The time interval was too small.
Effect
The requested operation aborts.
Recovery
Retry the operation with a time interval equal to or greater than one second.
3262
(ERR^NOCTRREC)
Cause
A counter record for the requested entity could not be found.
530 Error Codes