Measure Reference Manual
Cause
The PROCESSH code-range file did not specify any code ranges, or the existing code ranges
do not occur in the specified code space.
Effect
The requested operation aborts.
Recovery
Add at least one code range to the file or correct the code space specification and retry the
operation.
3268
(ERR^TOOMANYCRS)
Cause
The PROCESSH code-range file specified more than 500 code ranges.
Effect
The requested operation aborts.
Recovery
Delete enough code ranges from the file so that there are 500 or fewer and then retry the
operation.
3269
(ERR^CRTABLES)
Cause
The PROCESSH code-range table overflowed. Either the data file has been corrupted, or there
is a problem with MEASFH.
Effect
The requested operation aborts.
Recovery
If the data file was modified after the measurement was done, repeat the measurement and then
retry the operation. Otherwise, retain the data file and contact your HP representative.
3270
(ERR^EMPTYDATAFILE)
Cause
Read access was requested for a data file that contains no data.
Effect
The requested operation aborts.
Recovery
Use another data file with measurement data in it or start a measurement using this file.
3271
(ERR^CONTABFULL)
Cause
Too many PROCESSH code ranges are configured for measurement, and the CONTAB parameter
is full.
Effect
The requested operation aborts.