Measure Reference Manual

3276
(ERR^MEAS^NEVER^STARTED)
Cause
Either the measurement was not started correctly on this data file (and error 3410 (ERRM^INSTALL)
was returned by MEASMON), or START time was not written to the data file.
Effect
The data file does not contain valid data. Further operations on the data file could result in error.
Recovery
Try to start another measurement. Check the EMS log for error 3410 (ERRM^INSTALL). Use a
data file big enough that the START time can be written to the data file.
3277
(ERR^DATAFILE^CORRUPT)
Cause
MEASFH encountered an invalid data record when adding the data file.
Effect
The data file is analyzed only up to the invalid record.
Recovery
None possible. MEASFH cannot analyze the data file past the corrupted record.
3278
(ERR^CONTAB^NOT^COMPLETED)
Cause
The MEASREADCONF call is an earlier PVU than MEASFH.
Effect
MEASREADCONF could not handle an incomplete CONTAB parameter from MEASFH. It cannot
read large measurement configurations.
Recovery
Use a C20 or later PVU of the MEASREADCONF call.
3279
(ERR^CONVERTING^TO^RISC)
Cause
MEASFH was unable to convert a TNS address to a TNS/R address while processing the EDIT
file for SC or SL.
Effect
The measurement is not configured.
Recovery
Verify that each TNS address in the EDIT file is valid for the code space being configured. To
do so, check the CONFLIST in SYSTEM.SYSnn. Although Measure accepts any number from 0
through %177777 for a TNS address, if the code space was accelerated, only addresses mapped
by the NonStop operating system into a TNS/R address are accepted in the EDIT file.
3280
(ERR^FH^OLD^STRUCT^FILE)
Cause
The record size is different from the size in the data file.
534 Error Codes