Measure Reference Manual
Cause
The caller process has already opened MEASMON.
Effect
The requested operation aborts.
Recovery
The MEASMON process can be opened only once by the caller. It is already open. Check the
MEASCB structure passed to the callable procedure. The caller should not have modified it.
3315
(ERRM^START^MEASSUBSYS)
Cause
The backup for MEASMON did not start, one or more executing CPUs does not contain an
active MEASCTL or MEASIP process, or both.
Effect
The MEASURE subsystem is not fully operational.
Recovery
Correct the problems indicated by the console messages. Then stop the MEASURE subsystem
and restart it, ensuring that all MEASMON, MEASCTL, and MEASIP processes are stopped,
before restarting the subsystem.
3316
(ERRM^MEMLOCKFAILURE)
Cause
The call to the LOCKMEMORY procedure failed. MEASMON was not able to perform the security
check needed to access the data file.
Effect
The measurement was not started.
Recovery
Retry the request. If the problem persists, notify your system operator.
3317
(ERRM^INVALIDBINADDR)
Cause
An invalid code range was given in the PROCESSH entity.
Effect
The measurement does not run.
Recovery
Supply a valid code range address and retry.
3318
(ERRM^INVALIDBINPART)
Cause
The PROCESSH configuration was not sent to MEASMON. MEASMON was unable to configure
the measurement.
Effect
The measurement was not started.
Recovery
Retry the request. If the problem persists, contact your HP representative.
542 Error Codes