Measure Reference Manual
3319
(ERRM^NOBINADDRSPACE)
Cause
The pool space for code-range addresses is full in the MEASCTL process.
Effect
The measurement does not run.
Recovery
Stop some measurements and then try to start your measurement again.
3320
(ERRM^BACKUP^DATAFILEOPENFAILED)
Cause
An attempt by backup MEASMON to open the data file failed.
Effect
The requested operation aborts.
Recovery
Check the file system error number and take appropriate action.
3400
(ERRM^READLINKFAILED)
Cause
The complete request could not be read because the processor did not have sufficient physical
memory.
Effect
The reply file does not contain any data.
Recovery
Install more memory.
3401
(ERRM^BUFFERTOOSMALL)
Cause
The requestor’s buffer was too small to complete the request.
Effect
The reply file does not contain any data.
Recovery
Allocate more space for the reply and retry the operation.
3402
(ERRM^CANNOTACCESS)
Cause
The entity could not be accessed because of the current state. The CPU, group, module, slot
number, SCSI ID, SAC name, lun, partition number, or path entered for the device may not be
the correct value. Find out the correct value from SCF and retry the command.
Effect
The reply does not contain any data.
Recovery
If the device is inaccessible, contact your system operator.
543