Measure Reference Manual
Cause
No data records were encountered for the last output file, whose cpu-list was specified as
a wildcard (*) in the SPLIT command.
Effect
The SPLIT command continues. The specified output file is not created.
Recovery
Determine the reason for the missing data and decide whether this is a significant issue.
MEASFT 2011 (WARN_SPLIT_FILE_NOT_CREATED_2)
An output file was not created due to lack of data.
Cause
An output file name was not created because MEASFT found no data records that satisfied the
split criteria for that file. This warning is always preceded by message 2007 and occurs only
when an asterisk or a prefix followed by an asterisk was specified in the output file set.
Effect
The SPLIT command continues. The specified output file is not created.
Recovery
Remove the split criteria for the output file associated with this message. See the preceding
occurrence of message 2007 to know which split criterion caused the problem.
MEASFT 2032 (WARN_MISSING_JOURNAL)
journal-type Journal missing.
Cause
Expected journal was not encountered; journal-type can be either OSS or SQL.
Effect
The command continues.
Recovery
Check the file size of the Measure data file to see whether the file was truncated; truncation can
sometimes arise when you transfer a very large file. If the file was not truncated, it might be
corrupted. If neither of these cases seems to apply, report this message to your HP representative.
MEASFT 2033 (WARN_READ_INVALID_DATA)
An invalid record was found in Measure data file
Cause
A Measure data file has an invalid record. The record could be invalid because the disk where
the data file was collected was full or because the MEASCOM SWAP volume was full.
Effect
The command continues by marking the invalid record as the EOF of the Measure data file. The
rest of the records in the data file are ignored.
Recovery
Check the size of the disk where the Measure data file was collected or check the size of the
MEASCOM SWAP volume on the measurement system. If these are full, either relocate the file
to other disks or erase files to create more free space, and then re-run the measurement.
MEASFT 3000 (ERR_FNAME_RESOLVE)
Measfile Name Resolution failed, File System Error = #nn
Cause
A Measure data file name was specified that could not be resolved by FILENAME_RESOLVE_.
562 Measure Data File Tool (MEASFT)