Measure Reference Manual

Recovery
Either the Measure data file has been corrupted or MEASFT has a defect. Report this message
to your HP representative.
MEASFT 3027 (ERR_BAD_RECORD_STATE)
Bad record state in record #number
Cause
MEASFT encountered a record state it did not expect in record number.
Effect
The command does not complete. MEASFT terminates in error. Some output files may have been
created.
Recovery
Either the Measure data file has been corrupted or MEASFT has a defect. Report this message
to your HP representative.
MEASFT 3028 (ERR_BAD_DFFIRST_REC)
Measure data file corrupt, 1st record wrong length, file version Xnn
Cause
MEASFT did not recognize the first record in the Measure data file, whose version was Xnn.
Effect
The command is not executed. MEASFT terminates in error.
Recovery
Either the Measure data file has been corrupted or MEASFT has a defect. Report this message
to your HP representative.
MEASFT 3029 (ERR_UNEXPECTED_NONCTR_REC)
Unexpected non-counter record #number
Cause
MEASFT encountered a record type it did not expect in record number.
Effect
The command does not complete. MEASFT terminates in error. Some output files might have
been created.
Recovery
Either the Measure data file has been corrupted or MEASFT has a defect. Report this message
to your HP representative.
MEASFT 3030 (ERR_UNSUPPORTED_VERSION)
Unsupported Measure data file version, Xnn
Cause
MEASFT encountered a Measure data file version created by the Xnn version of Measure.
Effect
The command does not complete. MEASFT terminates in error
Recovery
MEASFT does not support data files created by Measure versions earlier than G10.
MEASFT 3031 (ERR_NO_DFFIRST_REC)
Measure data file corrupt, 1st record not present.
568 Measure Data File Tool (MEASFT)