Measure Reference Manual
Effect
The SPLIT command does not complete. MEASFT terminates in error.
Recovery
Use the displayed File System error number, nn, to determine what caused the error. This error
is unlikely to occur because the output file name has already been resolved by
FILENAME_RESOLVE_.
MEASFT 3234 (ERR_PARSE_SPLIT_RPAREN_MISSING)
SPLIT file specs right parenthesis missing.
Cause
The SPLIT file specifications entry starts with a left parenthesis and is missing a right parenthesis.
Effect
The SPLIT command does not complete. MEASFT terminates in error
Recovery
Correct the SPLIT file specifications syntax.
MEASFT 3235 (ERR_PARSE_SPLIT_BY_EXPECTED)
SPLIT 'BY' keyword missing.
Cause
The SPLIT split criteria entry must start with "BY".
Effect
The SPLIT command does not complete. MEASFT terminates in error
Recovery
Correct the SPLIT split criteria syntax.
MEASFT 3236 (ERR_PARSE_SPLIT_BY_KW_EXPECTED)
SPLIT 'BY CPU' or 'BY ENTITY' expected.
Cause
The SPLIT split criteria entry must start with "BY CPU" or "BY ENTITY".
Effect
The SPLIT command does not complete. MEASFT terminates in error
Recovery
Correct the SPLIT split criteria syntax.
MEASFT 3237 (ERR_PARSE_SPLIT_SC_RPAREN_MISSING)
SPLIT split criteria right parenthesis missing.
Cause
The SPLIT split criteria entry starts with a left parenthesis and is missing a right parenthesis.
Effect
The SPLIT command does not complete. MEASFT terminates in error
Recovery
Correct the SPLIT split criteria syntax.
MEASFT 3238 (ERR_PARSE_SPLIT_SC_MISMATCH)
SPLIT file specs and split criteria mismatch.
Cause
The SPLIT file specifications and split criteria entries conflict in the number of output files specified.
572 Measure Data File Tool (MEASFT)