Measure Reference Manual
MEASFT 3262 (ERR_PARSE_SPLIT_TIME_WC)
SPLIT, BY TIME * command not allowed.
Cause
The wildcard is not allowed in the SPLIT BY TIME command.
Effect
The SPLIT command does not complete. MEASFT terminates in error.
Recovery
Correct the SPLIT BY TIME syntax.
MEASFT 3300 (ERR_CANNOT_SPLIT)
The specified measure file cannot be split by entity, try splitting by
CPU.
Cause
The Measure data file contains data records for only one entity, so it cannot be split by entity.
This error occurs only when no split criterion is specified; by default, MEASFT attempts to split
the data file by entity.
Cause
The SPLIT command is not executed. MEASFT terminates in error.
Recovery
Try splitting by CPU.
MEASFT 3301 (ERR_CANNOT_SPLIT_BY_TIME)
Only H01 and later data files can be split by TIME, file version VNN.
Cause
The Measure data file is a pre-H01 data file.
Effect
The SPLIT command does not complete. MEASFT terminates in error.
Recovery
None.
MEASFT 4000 (ERR_PROCHAND_GETMINE)
PROCESSHANDLE_GETMINE_ Error = #nn
Cause
MEASFT encountered error nn in PROCESSHANDLE_GETMINE_
Effect
The SPLIT command is not executed. MEASFT abends.
Recovery
Contact HP.
MEASFT 4001 (ERR_PROCHAND_DECOMP)
PROCESSHANDLE_DECOMPOSE_ File System Error = #nn
Cause
MEASFT encountered File System error nn in PROCESSHANDLE_DECOMPOSE_
Effect
The SPLIT command is not executed. MEASFT abends.
Recovery
Contact HP.
578 Measure Data File Tool (MEASFT)