Measure User's Guide

Formatting Reports and Plots
Measure User’s Guide520560-003
4-4
REPORT Attributes
Resetting REPORT Attributes
To reset a REPORT attribute to its initial default setting, use the RESET REPORT
command. For example, to reset the FORMAT attribute to its initial default value:
9+ RESET REPORT FORMAT
10+ SHOW REPORT FORMAT
Set Report Format normal
To reset all REPORT attributes to their initial defaults, use an asterisk in the RESET
command. For example:
11+ RESET REPORT *
12+ SHOW REPORT *
Set Report Dots off
Set Report Format normal
Set Report Rate on
DOTS Specifies whether displays include a string of dots between counter
labels and a formatted numeric value (Measure G11 and later).
ON adds dots to the report display.
OFF formats spaces between labels and numeric
values (default).
LOADID loadid Specifies the name to be put in the LOADID field of the records
generated by this command.
CR-NAME-LEN Controls the displayed length of procedure (code-range) names:
SHORT truncates procedure (code-range) names (if
necessary) at 32 characters.
LONG displays both short and long forms of procedure
names.
CR-NAME-FORM Controls whether demangled procedure (code-range) names are
displayed (if applicable):
STANDARD displays whatever form was specified in the
code file (mangled) or EDIT file (demangled).
STANDARD is the default.
DEMANGLED displays demangled procedure names.
BOTH displays both STANDARD and DEMANGLED
procedure names.
CR-NAME-QUAL Controls whether procedure (code-range) names are displayed with
object file name qualifiers, if available:
UNQUALIFIED displays in traditional form with no qualifiers
(default).
QUALIFIED with the Guardian or OSS object file name of
the associated code.
Table 4-1. MEASCOM REPORT Attributes (page 2 of 2)
Attribute Description