NBX Manual

NBX Event Messages
NBX Manual424774-001
A-2
znbx-evt-auto-add-fail
znbx-evt-auto-add-fail
Cause. An attempt to automatically add a 6530 window has failed. This occurs when
AUTO^ADD is set to Y and an application, such as TACL or Pathway, opens NBX
using an undefined window name. This almost always is the result of a buffer pool
shortage.
Effect. The window is not added, so the application window will not be available for
remote NBX 6530 users.
Recovery. Use the NBXCOM POOL command to check buffer pool utilization. If
required, change PARAM POOL^SIZE and restart NBX.
znbx-evt-backup-loop
Cause. Attempts to create the backup process repeatedly failed.
Effect. NBX will set BACKUPCPU to NONE.
Recovery. If the failure is due to a specific processor being unavailable, use the
NBXCOM BACKUPCPU command to specify another backup processor number. For
other failure reasons, contact your Compaq support representative.
znbx-evt-backup-start-err
Cause. NBX could not create a backup process.
Effect. status1 and status2 are the results of NEWPROCESS. NBX will retry the
request.
Recovery. No action is required.
znbx-evt-backup-started
Cause. NBX started a backup process in processor cpunum.
Effect. This message is given for your information only.
Recovery. No action is required.
pname Automatic ADD WIN failure window
pname Backup creation loop - BACKUPCPU NONE assumed
pname Backup create error status1 status2
pname Backup created in cpu cpunum