NBX Manual

NBX Event Messages
NBX Manual424774-001
A-7
znbx-evt-stopping
znbx-evt-stopping
Cause. An NBXCOM SHUTDOWN command was received.
Effect. NBX stops immediately, returning error code 201 to any outstanding application
file system requests, and terminating any active sessions with remote nodes. If the
backup was running, a separate znbx-evt-event-backup-stopped event is generated. The
TACL STOP process-name command can equivalently be used to stop NBX.
Recovery. No action is required.
znbx-evt-takeover
Cause. The NBX backup process became the primary process.
Effect. reason explains the manner in which the primary process stopped.
Recovery. If the failure is due to a primary process failure, check for other events that
would indicate an NBX failure. NBX will automatically restart a new backup whenever
the appropriate processor is available.
znbx-evt-trace-error
Cause. The trace file was not opened to disk file fname. status1 and status2 are internal
NBX variables.
Effect. The trace was not started.
Recovery. Report this problem to your Compaq support representative.
znbx-evt-trace-object
Cause. A trace file could not be opened because of a problem reading the NBX object
file.
Effect. The trace mechanism needs to copy finite-state machine transition tables from
the object files to the trace file, which are used later by NBXGTRED.
Recovery. Verify that the object file is secured to allow read access to the user ID of
the NBX process. If the problem persists, contact your Compaq support representative.
pname Process stopping - SHUTDOWN command
pname Backup process takeover due to: reason
pname Trace not started to fname size size error status1 /
status2
pname Trace not started to fname; error reading object file