NetBatch-Plus Reference Manual
Installation, Startup, and Shutdown
NetBatch-Plus Reference Manual—522461-002
2-8
Installation Example
k. Indicate the Guardian name of the output file for the server class (can be a
device, disk file, or process):
Out terminal “\node.$device” ................: $s
l. Specify the timeout period (in seconds) for NetBatch-Plus screens and the
action taken when the period expires:
Time-out value (>= 300 sec) for PATHWAY server: 300
The timeout period determines how long NetBatch-Plus displays a screen after
use. When the timeout period expires on any screen beside the Main Menu,
the Main Menu screen is redisplayed.
If the value is not an exact power of two, NetBatch-Plus converts it to the next
higher power of two to give the actual timeout period. For example, 300
converts to an actual timeout period of 512 seconds (2
9
) or 8.5 minutes.
m. Specify whether to exit NetBatch-Plus on timeout on the Main Menu screen:
Exit NetBatch-Plus on timeout? Y/N [Y]: N
When the timeout period expires on the Main Menu screen:
•
If you entered Y (Yes) at the INSTALL prompt “Exit NetBatch-Plus on
time-out?”, NetBatch-Plus ends the PATHWAY session.
•
If you entered N (No) at the prompt, the Main Menu screen remains but
NetBatch-Plus logs off the signed-on user.
n. Specify the Guardian name of the default output file (device or process) for
screen copies printed by the NetBatch-Plus screen print function SF13–Print:
Print file for screen (device or process)....: $s.#prt
To change the output file after installation, modify the PATHCONF file or the
NRUN macro. For information on changing the output file, see Specifying the
Output File for the SF13–Print Function on page 3-5.
o. Specify whether to enable the Audit Trail Facility:
Enable Audit Trail Facility (Y/[N])..........: n
p. Specify whether HIGHPIN is on for TCP (if so, you can use only systems
running D-series or G-series RVUs to run NetBatch-Plus):
If TCP HIGHPIN ON, only terminals on D-series systems can
be used
TCP HIGHPIN (ON/[OFF]) <OFF> ................: ON
q. Specify whether HIGHPIN is on for the Utility server (if so, you can use only
systems running D-series or G-series RVUs to run NetBatch-Plus):
If Utility server has HIGHPIN ON, only terminals on
D-series systems can be used. Only utilities that tolerate
a high PIN requester will run.
Utility Server HIGHPIN (ON/[OFF])............: ON