NET/MASTER Management Services (MS) Command Reference Manual
LBANNER
LINK DEFINE
NonStop NET/MASTER MS Commands
115412 Tandem Computers Incorporated 2–137
5. The following example defines an X.25 link between a local Tandem system
running NonStop NET/MASTER MS (\LOC1) and a remote Tandem system
running NonStop NET/MASTER MS (\RMT1). It defines two units under each
session definition record.
Note For convenience, the components that create the hierarchical relationship among the link definition
record, the session definition record, and the unit definition records are underlined.
\LOC1:
LINK DEFINE=RMT1 MSGID=RMT1 HLITE=REVERSE BKGCOLOR=BLUE
COMMENT=\RMT1
SESSION DEFINE=RMT1S LINK=RMT1 TYPE=X25 APPLID=APPL01
COMMENT=\RMT1
UNIT DEFINE=RMT1U1 SESSION=RMT1S MODE=PERMANENT
IOSIZE=128 CONNECTDELAY=60
DEVICE=\LOC1.$X2501.#PVC01
COMMENT=\RMT1
UNIT DEFINE=RMT1U2 SESSION=RMT1S MODE=ACTIVE
IOSIZE=256 CONNECTDELAY=120 DTEADDR=01234567891201
DEVICE=\LOC1.$X2502.#SVC01
COMMENT=\RMT1
\RMT1:
LINK DEFINE=LOC1 MSGID=LOC1 HLITE=BLINK COLOR=RED
COMMENT=\LOC1
SESSION DEFINE=LOC1S LINK=LOC1 TYPE=X25 APPLID=APPL01
COMMENT=\LOC1
UNIT DEFINE=LOC1U1 SESSION=LOC1S MODE=PERMANENT
IOSIZE=128 CONNECTDELAY=61
DEVICE=\RMT1.$X2501.#PVC01
COMMENT=\LOC1
UNIT DEFINE=LOC1U2 SESSION=LOC1S MODE=PASSIVE
IOSIZE=256 CONNECTDELAY=121
DEVICE=\RMT1.$X2502.#SVC01
COMMENT=\LOC1