NET/MASTER Management Services (MS) Command Reference Manual
LBANNER
SYSPARMS TOTIME1
NonStop NET/MASTER MS Commands
2–542 115412 Tandem Computers Incorporated
TOTIME1
TOTIME1=
timeout-interval-1
specifies the time interval to use as the first timeout period for inactive terminals.
Any terminal that is inactive for the specified time interval triggers the action
specified by the SYSPARMS TOACT1 command.
You must set a first timeout period before setting a second timeout period.
timeout-interval-1
specifies the interval. The default value is 0.00. This value suppresses all
terminal timeout inactivity processing. You can specify a timeout period in
the form:
mmm
.
ss
mmm
specifies the number of minutes. You can specify a value from 0 through
999.
ss
specifies the number of seconds. You can specify a value from 0 through
59.
Example
The following example specifies a time interval of 10 minutes:
SYSPARMS TOTIME1=10.00