NET/MASTER Management Services (MS) Operator's Guide
Responding to Prompts Generated by Utilities
Accessing External Utilities and Applications
106379 Tandem Computers Incorporated 7–15
3. Press F14 (PF14). The following screen appears.
(09:31) --------------------- OPERATOR CONTROL SERVICES ----------------------
START OPSYS SEND FUP1 PURGE $DATA.MYVOL.*
NNM1456 DO YOU WISH TO PURGE THE ENTIRE SUBVOLUME $DATA.MYVOL
|NM1456 [100,021 FUP1] ( Y[ES], N[ONE], S[ELECT], F[ILES] )?
NNM0999 *END*
NNM1456 CODE EOF LAST MODIF OWNER RWEP TYPE
REC BLOCK
NNM1456 $DATA.MYVOL
NNM1456 AAAA 101 0 9:27 100,21 NCNC
NNM1456 [100,021 FUP1] PURGE?
NNM0999 *END*
_____________________________________________________________________________
---------- ------------------ NonStop NET/MASTER D30 ---------------- --------
M=> S
(If you are in the Command Entry facility, type S in the COMMAND field and press
F14 (PF14) to issue the command.)
You respond to each confirmation prompt as follows:
1. Type your response at the command input line.
2. Position the cursor to the left of the prompt:
NNM1456 [100,021 FUP1] PURGE?