NET/MASTER Management Services (MS) Operator's Guide
Ending a Session With a Utility
Accessing External Utilities and Applications
106379 Tandem Computers Incorporated 7–17
You decide that the command is returning more information than you need and issue
a BREAK command to stop the output (if you are in the Command Entry facility, press
SF13 to issue the command):
OPSYS BREAK FUP1
(10:10) --------------------- OPERATOR CONTROL SERVICES ----------------------
NNM1456 ZEX0616N 101 2442 10NOV94 14:24 100,21 NCNC
NNM1456 ZEX0617N 101 2440 10NOV94 14:24 100,21 NCNC
NNM1456 ZEX0618N 101 2464 10NOV94 14:24 100,21 NCNC
NNM1456 ZEX0619N 101 2740 10NOV94 14:24 100,21 NCNC
NNM1456 ZEX0620N 101 2738 10NOV94 14:24 100,21 NCNC
NNM1456 ZEX0621N 101 2766 10NOV94 14:24 100,21 NCNC
NNM1456 ZEX0622N 101 2878 10NOV94 14:24 100,21 NCNC
NNM1456 ZEX0623N 101 2388 10NOV94 14:24 100,21 NCNC
NNM1456 ZEX0624N 101 2500 10NOV94 14:25 100,21 NCNC
NNM1456 ZEX0625N 101 2532 10NOV94 14:25 100,21 NCNC
NNM1456 ZEX0701N 101 2180 10NOV94 14:25 100,21 NCNC
NNM1456 ZEX0702N 101 2232 10NOV94 14:25 100,21 NCNC
NNM1456 ZEX0703N 101 2228 10NOV94 14:25 100,21 NCNC
NNM1469 (-404) Command Pre-empted
NNM0999 *END*
NNM0995 REQUEST COMPLETE
_____________________________________________________________________________
NNM1456 ZEX0612N 101 2332 10NOV94 14:24 100,21 NCNC
NNM1456 ZEX0613N 101 2330 10NOV94 14:24 100,21 NCNC
NNM1456 ZEX0614N 101 2512 10NOV94 14:24 100,21 NCNC
NNM1456 ZEX0615N 101 2638 10NOV94 14:24 100,21 NCNC
---------- ------------------ NonStop NET/MASTER D30 ---------------- --------
M=> OPSYS BREAK FUP1
Ending a Session With a
Utility
When you exit the environment in which you are interacting with Guardian utilities,
all utility sessions established within that environment are terminated.
You can also explicitly terminate Guardian utility sessions by using the OPSYS
CLEANUP and KILL commands.
KILL The KILL command terminates an individual utility session
immediately, without regard to any outstanding requests. You
cannot KILL a session started under a different GUID. If you are in
the Command Entry facility, you can use the SF14 function key to
issue the command.
CLEANUP The CLEANUP command terminates all utility sessions associated
with your current NonStop NET/MASTER MS environment,
regardless of the GUIDs associated with the sessions. If you are in
the Command Entry facility, either prefix the OPSYS CLEANUP
command with a slash (/) or enter spaces in the UTILITY field.
Refer to the User’s Guide to DSNM Commands for more information on the KILL and
CLEANUP commands.
The following example sends a LOAD request to FUP1:
OPSYS SEND FUP1 LOAD LONG, $HUGE.BIG.DATABASE