NET/MASTER Management Services (MS) System Management Guide
Contents of a Utility Definition Record
Managing Access to External Utilities and Applications
6–12 115414 NonStop NET/MASTER MS System Management Guide
Table 6-3. UMS : Utility Details Panel: Page 1 Fields (Page 2 of 2)
Field Description Valid Values Default
Value
Length less
than
Specifies, in number of characters, the length of
a character string that is not considered a
command prompt.
Integer in the range of 2
through 99.
None
Ending with this
character
Specifies the character with which a utility
command prompt always ends; enter data in this
field only if the “Length less than” field contains
data.
Any displayable character. None
Matching this
pattern
Specifies the regular expression that matches
prompt text that should be considered a
command prompt. See Appendix E, “Regular
Expressions,” for more information about regular
expressions.
Up to 60 characters; the two
30-character fields on the panel
are concatenated and treated as
one field.
None
CPU The CPU in which the utility program executes. An integer in the range of 0 to 15. None
Priority Specifies the execution priority of the utility
program.
An integer in the range of 1
through 199.
None
Process name Gives the name of the utility program process. A valid process name. None