NET/MASTER Messages Manual

NNM0814
Messages
106159 Tandem Computers Incorporated 2–167
NNM0813 ERROR OPENING DISTRIBUTOR
dname
ERROR
errno
Cause. The NonStop NET/MASTER MS distributor interface failed to open the event
distributor.
dname
is the name of the event distributor.
errno
is the Guardian file-system error number.
Effect. The distributor interface is stopped and flagged as unavailable for use.
Recovery. Use the error number to determine the appropriate action to take. After you
have rectified the problem, use the EMSDIST START command to restart the interface.
NNM0814 EMS DISTRIBUTOR CONFIGURATION ERROR=
ems_error
, FILE
ERROR=
errno
, LOGFILE
logname
, COLLECTOR
collname
Cause. An EMSDIST START command was issued, but the EMSDISTCOLL system
parameter contains an invalid collector name; or a SYSPARMS EMSDISTCOLL
command was issued with an invalid collector name while the NonStop
NET/MASTER MS distributor interface was active; or the distributor could not access
an event log file.
ems_error
is the EMS distributor error number.
errno
is the Guardian file-system error number.
logname
is the name of the log file the collector is trying to access.
collname
is the collector name that was used by the distributor.
Effect. The distributor interface is stopped and flagged as unavailable for use.
Recovery. Use the error numbers to determine the appropriate action to take. After
you have rectified the problem, use the EMSDIST START command to restart the
interface.