NET/MASTER Messages Manual

NNM0821
Messages
2–170 106159 Tandem Computers Incorporated
NNM0821 NEWPROCESS ERROR ON
process_name
ERROR
err1
/
err2
Cause. An EMSDIST START command was issued. The NonStop NET/MASTER MS
distributor interface tried to start the process named in the EMSDISTPFN system
parameter but encountered an error.
process_name
is the name of the process specified in EMSDISTPFN.
err1
is the NEWPROCESS error number.
err2
is the NEWPROCESS error subcode or a file-system error
number.
Effect. The distributor interface is stopped and flagged as unavailable for use.
Recovery. Use the error code returned by the Guardian procedure NEWPROCESS to
determine the appropriate action to take. After you have rectified the problem, retry
the command.
NNM0822 ERROR OPENING COLLECTOR
collname
ERROR
errno
Cause. An EMSCOLL START command was issued. The NonStop NET/MASTER MS
collector interface tried to establish a path to the collector named in the EMSCOLLPFN
system parameter but encountered an error.
collname
is the name of the collector specified in EMSCOLLPFN.
errno
is the Guardian file-system error number.
Effect. The collector interface is stopped and flagged as unavailable for use.
Recovery. Use the error number to determine the appropriate action to take. After you
have corrected the problem, retry the command.
NNM0823 COLLECTOR UNAVAILABLE FOR USE
Cause. An EMSCOLL STOP command was issued or an error occurred. If the message
appears as a result of an error, there will be other messages that provide information
about the error.
Effect. The collector interface no longer processes events.
Recovery. If the message appears as a result of an error, refer to accompanying
messages to determine the appropriate action to take; otherwise, you do not need to
take any action.