NET/MASTER Messages Manual
NNM0836
Messages
2–174 106159 Tandem Computers Incorporated
NNM0836 ERROR
err1
/
err2
ACCESSING EVENTTD FILE
filename
Cause. An error occurred while retrieving help on an EMS event message.
err1
is the first part of the EMSTEXT procedure error code.
err2
is the second part of the EMSTEXT procedure error code.
filename
identifies the EMS events help file.
Effect. No help is retrieved.
Recovery. Use the error code returned by the EMSTEXT procedure to determine the
appropriate action to take. (Refer to the EMS Manual for the description of the code.)
While the problem is being corrected, you can use the SYSPARMS EMSEVENTTD
command to open a different EMS events help file for use.
NNM0837 COLLECTOR ERROR
ems_error
Cause. The collector interface thread received an error during an I/O operation.
ems_error
is an error number, indicating either a specific EMS collector error or an
Operating System error.
Effect. The collector interface is stopped and is flagged as unavailable for use. All
outstanding messages using this interface will be returned in error.
Recovery. Use the error number to determine the appropriate action to take. Correct
the problem and use the EMSCOLL START command to restart the interface.
NNM0850 CONNECTED
Cause. An initial SIGNON or ROUTE command was issued, and the ROC sign-on to a
remote system was successful.
Effect. The sign-on to the remote system is successful.
Recovery. This message is informational only; no recovery action is necessary.
NNM0852 SIGNON RESTART IN PROGRESS
Cause. The reestablishment of a disrupted ROC connection is in progress.
Effect. Signon processing is scheduled at the remote system.
Recovery. This message is informational only; no recovery action is necessary.