NET/MASTER Messages Manual

NNM0856
Messages
2–176 106159 Tandem Computers Incorporated
NNM0856 SIGNON RESTART FOR
linkname
NO LONGER IN EFFECT
Cause. A LINK RESET command was issued, and the link reset occurred while the
ROC connection was waiting for reestablishment due to a link failure. The connection
was lost.
linkname
is the name of the INMC link that was reset.
Effect. The ROC connection is lost.
Recovery. To reestablish the connection, wait for the link to be restarted and then sign
on to the remote system. You can use the SHOW LINKS command to check the status
of the link.
NNM0857 QUEUED SIGNON
linkname
CANCELED, LINK DEFINITION RESET
Cause. A LINK RESET command was issued, and the link reset occurred while the
signon request was waiting for the link to the remote system to become active. The
request was canceled.
linkname
is the name of the INMC link that was reset.
Effect. The signon is canceled.
Recovery. Wait for the link to be restarted and then sign on to the remote system.
NNM0858 NO COMMAND TEXT SPECIFIED
Cause. A ROUTE command was issued but the command string to be sent to the
remote system was not specified.
Effect. No command is routed to the remote system.
Recovery. Retry the command with the required command string.
NNM0859 INSUFFICIENT STORAGE TO PROCESS COMMAND, RETRY
Cause. A ROUTE command was issued but a temporary memory shortage caused the
command to fail.
Effect. The specified command string is not routed to the remote system.
Recovery. Retry the command. If the condition persists, refer the message to your
system manager.