NET/MASTER Messages Manual
NNM0879
Messages
106159 Tandem Computers Incorporated 2–181
NNM0876 REMOTE USER LOGON ATTEMPT FAILED SECURITY CHECK - SIGNON
FAILED
Cause. A SIGNON or a ROUTE command was issued to try to sign on to a remote
system but the security check failed.
Effect. The remote system refuses the signon request.
Recovery. Ensure that the remote system knows your user ID. If your password at the
remote system is different from your password at the local NonStop NET/MASTER
MS system, ensure that you supply the correct password with your SIGNON
command. You cannot use the ROUTE command to sign on to a remote system if your
local password is different from your remote password. (There is no PASSWORD
operand on the ROUTE command.)
NNM0877 REMOTE USER SIGNON FAILED - NO MEMORY AVAILABLE
Cause. An initial SIGNON or ROUTE command was issued but a temporary memory
shortage at the remote system caused the signon to fail.
Effect. The remote system cannot process the signon request.
Recovery. Retry the command. If the condition persists, refer the message and the
name of the INMC link to your system manager.
NNM0878 REMOTE USER SIGNED OFF - NO MEMORY AVAILABLE
Cause. A temporary memory shortage at the remote system caused the ROC session to
fail.
Effect. The remote system signs off the user.
Recovery. Enter another SIGNON command. If the condition persists, refer the
message and the name of the INMC link to your system manager.
NNM0879 INVALID MSGID
msgid
SPECIFIED IN COMMAND
Cause. A SIGNON command was issued but an invalid message ID was specified. A
message ID must be one through eight characters long.
msgid
is the specified message ID.
Effect. The signon is not processed.
Recovery. Specify a valid message ID and retry the command.