2–292 106159 Tandem Computers Incorporated
NNM1552
process_name
LOGON FAILED: ERROR=
error
Cause. The logon failed because of a failed request to the NonStop NET/MASTER MS
control process.
error
is either a Guardian file-system error number or some error text. Error
text is one of the following:
CLOSTERM COMMAND
There was a CLOSTERM command for the terminal, or the NonStop
NET/MASTER MS system is shutting down. If necessary, check who else has
modified the status of the specified terminal.
ERROR=
nnn
[ SNASENSE=
xxxxxxxx
]
nnn
is the Guardian file-system error number.
xxxxxxxx
is the SNA sense code (for IBM 3270 terminals only).
Refer the message to your system manager. The manager can use the error
number and the sense code to determine the appropriate action to take.
INVALID TERMINAL DATA
The NonStop NET/MASTER MS system received invalid data from the terminal.
The condition may occur when a TACL program (or some other program)
competes with the NonStop NET/MASTER MS system for access to the terminal.
Ensure that:
Any TACL or COMINT program running on the terminal is paused, for
example, through the PAUSE command
No other programs are accessing the terminal
There are no faults with the physical connection of the terminal
INVALID TERMINAL TYPE
The terminal is of an unsupported type. Supported types are the IBM 3270 and
Tandem 6530 class of devices. Ensure that the terminal is of the correct type or is
emulating a terminal of the correct type.
MAXIMUM NUMBER OF USERS EXCEEDED
The NonStop NET/MASTER MS system could not take on another user and
rejected the logon request. The system manager can log off inactive users, or use
the SYSPARMS MAXUSERS command to increase the allowed number of users.