NET/MASTER Messages Manual

2198: ZNNM-EVT-TOO-MANY-SAME-AS
Event-Message Tokens
4–70 106159 Tandem Computers Incorporated
2198: ZNNM-EVT-TOO-MANY-SAME-AS
More than five command sets were examined in one request due to the use of the
“Same as” field in the definitions.
Tokens
Token Name Token Type Value Assigned
ZEMS-TKN-EVENTNUMBER ZSPI-TYP-INT 2198
ZEMS-TKN-EMPHASIS ZSPI-TYP-BOOLEAN FALSE
ZSPI-TKN-SSID ZSPI-TYP-SSID 117
ZEMS-TKN-SUBJECT-MARK ZSPI-TYP-MARK (See description)
ZNNM-TKN-SECNAME ZSPI-TYP-STRING SECURITY-EXIT
ZNNM-TKN-UTILITY-NAME ZSPI-TYP-STRING (See description)
ZNNM-TKN-UTILITY-TYPE ZSPI-TYP-CHAR (See description)
Event-Message Text
TOO MANY "SAME AS" REFERRALS FOR
name
type
where:
name
is the value of
ZNNM-TKN-UTILITY-NAME
type
is the value of
ZNNM-TKN-UTILITY-TYPE
ZEMS-TKN-SUBJECT-MARK
marks the next token in the event-message buffer as a subject token of the event
message.
ZNNM-TKN-UTILITY-NAME
contains the utility name at the start of the referral list. It appears as
name
in the
message text.
ZNNM-TKN-UTILITY-TYPE
contains the utility type at the start of the referral list. It can be:
O for an OPSYS utility.
P for a PROGRUN utility.
S for a special record rather than a utility. Special records are used to hold the
command authority for unrestricted PROGRUN access, and the list of users
that are allowed to update the Utility Access database.
It appears as
type
in the message text.