NET/MASTER RMS Management and Operations Guide

Testing Rules Against a Set of Messages
Testing Rules Using Simulated Events
8–14 115415 NonStop NET/MASTER RMS Management and Operations Guide
Adding or Modifying a Message
You can add a message that is based on an existing message in the message set. When
you add a message, RMS creates a copy of the model message that you can modify.
Also, you can modify a message. On the RMS : Captured Message Set Edit panel, type
an A or S next to the message you want to add or modify and press ENTER. The
RMS : Saved Message Editing panel appears.
SDPL-------------------- RMS : Saved Message Editing ------------------ZRMSD11P
Command ===>
MESSAGE COMPONENTS
Message ID ..... NNM0652˚˚˚˚˚
SS ID .......... ˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚
Domain ID ...... SDPL˚˚˚˚ (Originating Domain ID)
Process Name ... ˚˚˚˚˚˚˚˚˚˚˚˚˚ (Originating Process Name)
MESSAGE ATTRIBUTES
Day ............ THU (MON,TUE,...)
Time ........... 14:37:12 (HH:MM:SS)
MESSAGE TEXT
LOCAL USER NMTHY LOGGED ON AT #0206837 -- HENRY YAO˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚
˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚
˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚
˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚
˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚˚
F1=Help F2=Split F3=File F9=Swap F12=Cancel
You can modify the following:
The message recognition elements in the Message ID and SS ID fields: message ID
and ID of the subsystem that generates the message (for example,
TANDEM.NNM.C31 is the NonStop NET/MASTER MS subsystem).
Source of the message in the Domain ID and Process Name fields: the domain ID
of the NonStop NET/MASTER MS or the SOLVE management services system
from which the message comes, and the name of the process that sends the
message.
Time of message arrival by time of day in the Day and Time fields as follows:
Day must be one of MON, TUE, WED, THU, FRI, SAT, and SUN.
Time must be in the range 00:00:00 through 23:59:59. The default is 00:00:01.
You can omit the 00 strings. For example, ::01 is the same as 00:00:01.
Text of the message: the text starts with the second word of the message.
Press F3 to file your modifications.