NET/MASTER RMS Management and Operations Guide

RMS6317
RMS Messages
115415 NonStop NET/MASTER RMS Management and Operations Guide A–95
Recovery. Specify a value in the Every field before requesting the action again. The
value is a time interval in the format hh:mm:ss, and between the value specified in the
EVCMDMIN system parameter and 24:00:00, inclusive. The value indicates the time
interval at which you want the rule actions repeated. Alternatively, if you want the
rule actions performed only once on specified days or a date, delete the value in the
Limit field before requesting the action again.
RMS6315 LIMIT MUST BE SPECIFIED IF FREQUENCY SPECIFIED
Cause. You specified a value in the Every field but no value in the Limit field on your
Time-Based Rule Definition panel.
Effect. The action is not performed. The Limit field is highlighted.
Recovery. Specify a value in the Limit field before requesting the action again. Valid
values are in the range 1 through 999. The value indicates the maximum number of
times you want the rule actions repeated at the time interval specified in the Every
field. Alternatively, if you want the rule actions performed only once on specified
days or a date, delete the value in the Every field before requesting the action again.
RMS6316 MINIMUM FREQUENCY IS
minimum-repeat-interval
SECONDS
Cause. You specified an invalid value in the Every field on your Time-Based Rule
Definition panel. The value is less than the minimum value allowed,
minimum-repeat-interval
, which is the value specified in the EVCMDMIN
system parameter.
Effect. The value is not accepted. The action is not performed.
Recovery. Change the invalid value to a time interval that is greater than or equal to
minimum-repeat-interval
before requesting the action again. The interval is in
the format hh:mm:ss, and in the range
minimum-repeat-interval
through 24:00:00.
RMS6317 WARNING - TIMER DRIVER NOT ACTIVE
Cause. You added or modified a time-based rule in the RMS database through the
Time-Based Rule Maintenance option and saved the record with the Activation field
set to I (Immediate) or N (Immediate No Save), but the RMS timer driver NCL
procedure was not executing. The immediate loading of a time-based rule requires the
RMS timer driver to be active. Possible causes are as following:
An error, which may have occurred previous to the saving of this time-based rule,
has caused the timer driver to terminate.
The timer driver NCL procedure may have been flushed.