Warnings
Cause. The current object file is a PIC object file, and you specified the EXCLUDE
option in the LISTUNRESOLVED or LU on page 5-35.
Recovery. Reissue the LISTUNRESOLVED or LU on page 5-35 without the EXCLUDE
option.
Cause. The current object file is a PIC object file, and you specified the DETAIL
option in the LISTUNRESOLVED or LU on page 5-35.
Recovery. Reissue the LISTUNRESOLVED or LU on page 5-35 without the DETAIL
option.
Cause. noft encountered a dynamic section whose name it does not recognize, and
will not continue to process that section. This version of noft is probably older than
the object it is analyzing.
Recovery. Use a newer version of noft.
Cause. You are using XREFPROC or XP on page 5-49 and the object file is corrupt in
an unexpected way. noft is attempting to report a procedure name for a cross-
reference, but cannot find the expected matching symbol in the external symbol table.
Recovery. noft continues processing the remaining procedures in the object file.
*** WARNING *** [2013]:
LISTUNRESOLVED Exclude option not supported on PIC objects,
option ignored...
*** WARNING *** [2014]:
LISTUNRESOLVED Detail option not supported on PIC objects,
option ignored...
*** WARNING *** [2015]:
Unknown Dynamic section found: section-name, skipping this
section
*** WARNING *** [2016]:
External symbol table has no match for dynamic symbol: symbol