noft Manual (G06.26+)

noft Diagnostic Messages
noft Manual528273-001
4-13
Data Errors
Cause. noft could not find the opcode for the last address.
Recovery. Verify that the ICODE is dumped into a code section.
Cause. An internal table is corrupt.
Recovery. Restart noft and reenter the command.
Cause. Either the directory (pathname) specified in CD on page 3-5 is not present or
the subvolume-name specified in the SYSTEM or VOLUME on page 3-49 is not
present.
Recovery. Verify that the specified directory or subvolume exists. Restart noft to
return to the default directory or subvolume.
Cause. noft cannot find a procedure in the object file.
Recovery. Check the list of procedures to see if the procedure is in the object file. If
not, rebuild the object file.
Cause. Either the specified file is not present or it is neither a text file nor an edit file.
Recovery. Verify that the path to the OBEY command file is correct and that the
OBEY command file is a text file (in the OSS environment and on UNIX workstations)
or an edit file (in the Guardian environment).
*** DATA ERROR *** [1042]:
Unable to determine instruction.
*** DATA ERROR *** [1043]:
Unable to dump some unresolved items.
*** DATA ERROR *** [1044]:
Unable to locate current [directory|subvolume].
*** DATA ERROR *** [1045]:
Unable to find procedure in object file.
*** DATA ERROR *** [1046]:
Unable to open obey file: filename.