noft Manual (G06.27+, H06.03+, J06.03+)
noft Diagnostic Messages
noft Manual—528273-003
4-12
Data Errors
Recovery. Check the list of procedures to see if the procedure is actually in the object
code file. If not, rebuild the object code file.
1034
Cause. An internal table is corrupt.
Recovery. Restart noft and reissue the commands in question.
1035
Cause. noft cannot allocate memory for the run-time procedure table, probably
because noft has an internal problem.
Recovery. Give the object code file being examined and the series of commands that
you used to your service provider for analysis.
1036
Cause. The specified source file has been changed since the object code file was
created, so line number information is inaccurate.
Recovery. Do either of:
•
Recompile the newer source file and run noft again on the new object code file.
•
Specify a different source file by changing the location where noft looks for the
source files, using the appropriate commands for your environment:
*** DATA ERROR *** [1034]:
Some problem printing text.
*** DATA ERROR *** [1035]:
Some sort of problem reading runtime procedure table for
names.
*** DATA ERROR *** [1036]:
Source file newer than object file, innerlist may be
inaccurate.
Environment Commands
Guardian SYSTEM or VOLUME
OSS CD
UNIX CD