Data Errors
1046
Cause. Either the specified file is not present or it is neither a text file nor an edit file.
Recovery. Verify that the path to the OBEY command file is correct and that the
OBEY command file is a text file (in the OSS environment and on UNIX workstations)
or an edit file (in the Guardian environment).
1047
Cause. Either the loadfile is stripped, or the procedure table is corrupted.
Recovery. Rebuild the loadfile without stripping.
1048
Cause. FILE or F on page 3-17 encountered a problem when trying to SET
SCOPEPROC, SET SCOPESOURCE, and SET CASE to their defaults.
Recovery. Use RESET on page 3-44 to reset SCOPEPROC, SCOPESOURCE, and CASE
(or all the SET parameters) to their defaults, and then enter the desired new option
value.
1049
Cause. The first or second timestamp of the source files is unavailable.
Recovery. Verify that the source files are not corrupt.
1050
Cause. noft cannot find an instruction for the opcode at this address.
*** DATA ERROR *** [1046]:
Unable to open obey file: filename.
*** DATA ERROR *** [1047]:
Unable to read table-name procedure table, command ignored.
*** DATA ERROR *** [1048]:
Unable to reset option, please reset manually.
*** DATA ERROR *** [1049]:
Unable to retrieve [first|second] timestamp.
*** DATA ERROR *** [1050]:
Unable to scan instructions.