noft Manual (G06.27+, H06.03+, J06.03+)

noft Diagnostic Messages
noft Manual528273-003
4-23
Warnings
Recovery. Check the result in the Guardian Procedure Calls Reference Manual
(see SEGMENT_DEALLOCATE_). Based on that information, take appropriate action.
2013
Cause. The current object code file is a PIC object code file, and you specified the
EXCLUDE option in the LISTUNRESOLVED or LU on page 3-37.
Recovery. Reissue the LISTUNRESOLVED or LU on page 3-37 without the EXCLUDE
option.
2014
Cause. The current object code file is a PIC object code file, and you specified the
DETAIL option in the LISTUNRESOLVED or LU on page 3-37.
Recovery. Reissue the LISTUNRESOLVED or LU on page 3-37 without the DETAIL
option.
2015
Cause. noft encountered a dynamic section whose name it does not recognize and
does not continue to process that section. This version of noft is probably earlier than
the object it is analyzing.
Recovery. Use a later version of noft.
2016
Cause. You are using XREFPROC or XP on page 3-54, and the object code file is
corrupt in an unexpected way. noft is attempting to report a procedure name for a
cross-reference, but cannot find the expected matching symbol in the external symbol
table.
*** WARNING *** [2013]:
LISTUNRESOLVED Exclude option not supported on PIC objects,
option ignored...
*** WARNING *** [2014]:
LISTUNRESOLVED Detail option not supported on PIC objects,
option ignored...
*** WARNING *** [2015]:
Unknown Dynamic section found: section-name, skipping this
section
*** WARNING *** [2016]:
External symbol table has no match for dynamic symbol: symbol