NonStop Operating System Event Management Programming Manual

Storage Subsystem Event Messages (ZSTO)
HP NonStop Operating System Event Management Programming Manual520372-020
23-60
Messages
Conditional Tokens
Cause. The storage subsystem manager removed an object configured in the storage
subsystem and removed the object from the system configuration database.
Effect. The object name is no longer reserved.
Recovery. This is an informational message only; no corrective action is needed.
1023: ZSTO-EVT-ERROR-IN-SIFM
The storage subsystem manager received an error when communicating with the
SIFM.
Unconditional Tokens
Token Description
ZSTO-TKN-PATH Optional token containing the device path being used.
ZSTO-TKN-TERMINALPROCESS Name of the terminal.
Subject: ZSTO-TKN-OBJECT-NAME
Potentially critical event: No
Action event: No
Message sender: Storage subsystem manager process ($ZZSTO)
TMDS collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZSTO-TKN-OBJECT-NAME token-type ZSPI-TYP-STRING
ZSTO-TKN-IFM-ERROR token-type ZSTO-TYP-ENM-IFM-ERROR
ZSTO-TKN-SIFM-ACTION token-type ZSTO-TYP-ENM-SIFM-ACTION
Event-Message Text
SIFM error occurred when processing object-name.
Error Code: error-code ( error-message ).
Action: action-message.
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZSTO-EVT-
ERROR-IN-SIFM (1023).
ZEMS-TKN-XLDEVNAME Subject token that contains the device name.
ZCOM-TKN-OBJTYPE Enumerated type that contains the object type.
ZSTO-TKN-IFM-ERROR Error message.
ZSTO-TKN-SIFM-ACTION Action to be taken.