NonStop Operating System Event Management Programming Manual
Storage Subsystem Event Messages (ZSTO)
HP NonStop Operating System Event Management Programming Manual—520372-020
23-68
Messages
Unconditional Tokens
Conditional Tokens
Cause. The storage subsystem manager successfully added a CRU configuration to 
the system configuration database (SCD).
Effect. The new CRU is configured in the SCD.
Recovery. This is an informational message only; no corrective action is needed.
1032: ZSTO-EVT-CRU-INIT
The storage subsystem manager has successfully initialized a CRU.
Conditional Tokens
ZSTO-TKN-SAC-INSTANCE token-type ZSPI-TYP-INT2
ZSTO-TKN-SAC-TYPE token-type ZSTO-TYP-ENM-SAC-TYPE
ZCOM-TKN-OBJTYPE token-type ZCOM-TYP-ENM-OBJ
Event-Message Text
The Storage Subsystem Manager automatically
configured an cru-type in location (group, module, slot)
[ , SAC instance: sac-instance]
[ , SAC type: sac-type. ]
Name: object-name.
[ The cru-type is used as a object-type cru-type. ]
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZSTO-EVT-
CRU-CONFIGURED (1031).
ZSTO-TKN-OBJECT-NAME Object name.
ZSTO-TKN-CRU-TYPE CRU type.
ZEMS-MAP-PHYSICAL-ADDRESS Physical location of the CRU.
Token Description
ZSTO-TKN-SAC-INSTANCE Optional token containing the SAC instance.
ZSTO-TKN-SAC-TYPE Optional token containing the SAC type.
ZCOM-TKN-OBJTYPE Optional token that is an enumerated type that contains the 
object type.
Subject: ZSTO-TKN-OBJECT-NAME
Potentially critical event: No
Action event: No
Message sender: Storage subsystem manager process ($ZZSTO)
TMDS collector: Yes