Unconditional Tokens
Cause. The storage subsystem manager has successfully initialized a CRU.
Effect. A CRU is initialized.
Recovery. This is an informational message only; no corrective action is needed.
1033: ZSTO-EVT-CRU-INIT-FAILED
The storage subsystem manager failed to initialize a CRU. The event contains the
error number returned from the support function used (provided by either the SIFM or
extensible I/O (XIO)).
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZSTO-TKN-OBJECT-NAME token-type ZSPI-TYP-STRING
ZSTO-TKN-CRU-TYPE token-type ZSTO-TYP-ENM-CRU-TYPE
ZEMS-MAP-PHYSICAL-ADDRESS token-type ZEMS-DDL-PHYSICAL-
ADDRESS
Event-Message Text
cru-type object-name in location (group, module, slot)
initialized.
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZSTO-EVT-
CRU-INIT (1032).
ZSTO-TKN-OBJECT-NAME Object name.
ZSTO-TKN-CRU-TYPE CRU type.
ZEMS-MAP-PHYSICAL-ADDRESS Physical location of the CRU.
Subject: ZSTO-TKN-OBJECT-NAME
Potentially critical event: No
Action event: No
Message sender: Storage subsystem manager process ($ZZSTO)
TMDS collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZSTO-TKN-OBJECT-NAME token-type ZSPI-TYP-STRING
ZSTO-TKN-CRU-TYPE token-type ZSTO-TYP-ENM-CRU-TYPE
ZEMS-MAP-PHYSICAL-ADDRESS token-type ZEMS-DDL-PHYSICAL-
ADDRESS
ZSTO-TKN-IFM-ERROR token-type ZSTO-TYP-ENM-IFM-ERROR