NonStop Operating System Event Management Programming Manual

Storage Subsystem Event Messages (ZSTO)
HP NonStop Operating System Event Management Programming Manual520372-020
23-72
Messages
1035: ZSTO-EVT-POST-FAILED
The storage subsystem manager determined that the power-on self-test failed for a
CRU that was inserted.
Unconditional Tokens
Subject: ZSTO-TKN-OBJECT-NAME
Potentially critical event: No
Action event: No
Message sender: Storage subsystem manager process ($ZZSTO)
TMDS collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZSTO-TKN-OBJECT-NAME token-type ZSPI-TYP-STRING
ZSTO-TKN-CRU-TYPE token-type ZSTO-TYP-ENM-CRU-TYPE
ZEMS-MAP-PHYSICAL-ADDRESS token-type ZEMS-DDL-PHYSICAL-
ADDRESS
Conditional Tokens
ZSTO-TKN-SAC-INSTANCE token-type ZSPI-TYP-INT2
ZSTO-TKN-SAC-TYPE token-type ZSTO-TYP-ENM-SAC-TYPE
ZCOM-TKN-OBJTYPE token-type ZCOM-TYP-ENM-OBJ
Event-Message Text
Power On Self Test (POST) failed for cru-type object-name
in location(group, module, slot)
[, SAC instance: sac-instance]
[, SAC type: sac-type].
[, SAC usage: object-type].
cru-type cannot be initialized.
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZSTO-EVT-
CRU-POST-FAILED (1035).
ZSTO-TKN-OBJECT-NAME Object name.
ZSTO-TKN-CRU-TYPE CRU type.
ZEMS-MAP-PHYSICAL-ADDRESS Physical location of the CRU.