Storage Subsystem Event Messages (ZSTO)
HP NonStop Operating System Event Management Programming Manual520372-020
23-77
Messages
Cause. The storage subsystem manager detected a process startup I/O error. This is
caused by a failure to send startup messages to a process that was just launched.
Effect. The command is not executed.
Recovery. Retry the command. If the problem persists, see Recovery Action
Requiring Vendor Support on page 23-25.
1040: ZSTO-EVT-UNSUPPORTED-CRU
The storage subsystem manager received a hardware insertion event for a CRU it
does not support.
Unconditional Tokens
Cause. The storage subsystem manager received a hardware insertion event for a
CRU it does not support.
Effect. The CRU is ignored.
Recovery. Remove the unsupported CRU.
Subject: ZSTO-TKN-CRU-TYPE
Potentially critical event: No
Action event: No
Message sender: Storage subsystem manager process ($ZZSTO)
TMDS collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZSTO-TKN-CRU-TYPE token-type ZSTO-TYP-EMN-CRU-TYPE
ZEMS-MAP-PHYSICAL-ADDRESS token-type ZEMS-DDL-PHYSICAL-
ADDRESS
Event-Message Text
The cru-type inserted in location (group, module, slot)
is not supported by the Storage Subsystem Manager.
Attempt to configure this CRU failed.
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZSTO-EVT-
UNSUPPORTED-CRU (1040).
ZSTO-TKN-CRU-TYPE Enumerated type containing the CRU type.
ZEMS-MAP-PHYSICAL-ADDRESS Physical location of the CRU.