NonStop Operating System Event Management Programming Manual
Storage Subsystem Event Messages (ZSTO)
HP NonStop Operating System Event Management Programming Manual—520372-020
23-78
Messages
1041: ZSTO-EVT-CRU-OWNERSHIP
The storage subsystem manager detected that it cannot configure a CRU because the
slot where the CRU was inserted is already configured by another subsystem.
Unconditional Tokens
Cause. The storage subsystem manager detected that it cannot configure a CRU
because the slot where the CRU was inserted is already configured by another
subsystem.
Effect. The CRU was not configured.
Recovery. Place the CRU in the correct location or delete the configuration records of
the other subsystem for that slot.
Subject: ZSTO-TKN-CRU-TYPE
Potentially critical event: No
Action event: No
Message sender: Storage subsystem manager process ($ZZSTO)
TMDS collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZSTO-TKN-CRU-TYPE token-type ZSTO-TYP-EMN-CRU-TYPE
ZEMS-MAP-PHYSICAL-ADDRESS token-type ZEMS-DDL-PHYSICAL-
ADDRESS
Event-Message Text
The cru-type inserted in location (group, module, slot) is
already configured by another subsystem. The Storage
Subsystem Manager’s attempt to configure the cru-type failed.
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZSTO-EVT-
CRU-OWNERSHIP (1041).
ZSTO-TKN-CRU-TYPE Enumerated type containing the CRU type.
ZEMS-MAP-PHYSICAL-ADDRESS Physical location of the CRU.