NonStop Operating System Event Management Programming Manual
Storage Subsystem Event Messages (ZSTO)
HP NonStop Operating System Event Management Programming Manual—520372-020
23-86
Messages
Cause. The storage subsystem manager has deferred the configuration of a CRU.
This event is generated when the storage profile record forces the storage subsystem
manager to start the I/O process to complete the configuration of the CRU, and the
processors in which the I/O process is configured to run are not available.
Effect. The configuration of the CRU is not completed.
Recovery. Reload one of the required processors.
1049: ZSTO-EVT-BACKUP-START-ERROR
The storage subsystem encountered an error while attempting to notify a primary disk
process to launch its backup process.
Unconditional Tokens
Subject: ZEMS-TKN-XLDEVNAME
Potentially critical event: No
Action event: No
Message sender: Storage subsystem manager process ($ZZSTO)
TMDS collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZEMS-TKN-XLDEVNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZCOM-TYP-ENM-OBJ
ZEMS-TKN-SUBJECT-MARK token-type ZSPI-TYP-SSCTL
ZSPI-TKN-NEXTTOKEN token-type ZSPI-TYP-TOKENCODE
ZSTO-TKN-FILESYSTEMERROR token-type ZSPI-TYP-INT
Event-Message Text
Backup launch notification for object-type mark
next-token failed, error file-system-error.
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZSTO-EVT-
BACKUP-START-ERROR (1049).
ZEMS-TKN-XLDEVNAME Subject token that contains the device name.
ZCOM-TKN-OBJTYPE Token that contains the object type.
ZEMS-TKN-SUBJECT-MARK EMS token that marks the token that follows it in the
event message as a subject of the event. See the EMS
Manual for more information about this token.
ZSPI-TKN-NEXTTOKEN Contains the pointer to the next token code in the
buffer. See the SPI Programming Manual for more
information about this token.
ZSTO-TKN-FILESYSTEMERROR Number of the file-system error.