NonStop Operating System Event Management Programming Manual

Storage Subsystem Event Messages (ZSTO)
HP NonStop Operating System Event Management Programming Manual520372-020
23-99
Messages
Cause. The storage subsystem manager has detected that a CRU is not configured.
This event is generated during system load or when a hardware insertion event is
received. This event is generated only when storage automatic configuration is
disabled.
Effect. None. The CRU remains unconfigured.
Recovery. This is an informational message only; no corrective action is needed.
2005: ZSTO-EVT-CNFG-MISSING-CRU
The storage subsystem manager has detected that a configured CRU is not present in
the system.
Unconditional Tokens
Subject: ZEMS-TKN-XLDEVNAM
Potentially critical event: No
Action event: No
Message sender: Storage subsystem manager process ($ZZSTO)
TMDS collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZEMS-TKN-XLDEVNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZCOM-TYP-ENM-OBJ
ZEMS-MAP-PHYSICAL-ADDRESS token-type ZEMS-DDL-PHYSICAL-
ADDRESS
Conditional Tokens
ZSTO-TKN-SAC-INSTANCE token-type ZSPI-TYP-INT2
ZSTO-TKN-SAC-TYPE token-type ZSTO-TYP-ENM-SAC-TYPE
ZSTO-TKN-USAGE token-type ZCOM-TYP-ENM-OBJ
Event-Message Text
object-type device-name is not present in location
(group, module, slot)
[, SAC Instance: sac-instance]
[, SAC type: sac-type].
[, SAC usage: object-type].
Token Description (page 1 of 2)
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZSTO-EVT-
CNFG-MISSING-CRU (2005).
ZEMS-TKN-XLDEVNAME Subject token that contains the device name.