NonStop Operating System Event Management Programming Manual
Storage Subsystem Event Messages (ZSTO)
HP NonStop Operating System Event Management Programming Manual—520372-020
23-105
Messages
Unconditional Tokens
Cause. The storage subsystem manager reports that a user command has created an
inconsistency between the system configuration database and the SMF catalogs.
Effect. Inconsistency between the system configuration database and SMF catalogs
can result in the following:
SMF objects that are unusable.
SCF reporting incorrect data about the SMF objects.
Recovery. See the T1083 product softdoc for information about how to recognize and
recover from this type of inconsistency.
2505: ZSTO-EVT-SMF-LAUNCH-DELAY
The storage subsystem manager reports that an attempt to start the SMF Monitor
Process ($ZSMS) has been delayed or aborted.
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZSTO-TKN-OBJECT-NAME token-type ZSPI-TYP-STRING
ZSTO-TKN-COMMAND token-type ZSPI-TYP-STRING
ZSTO-TKN-ATTRIBUTE token-type ZSPI-TYP-STRING
ZSTO-TKN-OBJECT-TYPE token-type ZSPI-TYP-STRING
Event-Message Text
command object-type object-name [,attribute] has created
inconsistency between SMF catalogs and the CONFIG file.
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZSTO-EVT-SMF-
INCONSISTENCY (2504).
ZSTO-TKN-OBJECT-NAME Subject token that contains the object name.
ZSTO-TKN-COMMAND SCF command.
ZSTO-TKN-OBJECT-TYPE Enumerated type that contains the object type.
ZSTO-TKN-ATTRIBUTE Optional token that contains the SCF attribute.
Subject: ZEMS-TKN-XLDEVNAME
Potentially critical event: No
Action event: No
Message sender: Storage subsystem manager process ($ZZSTO)
TMDS collector: Yes