NonStop Operating System Event Management Programming Manual

Configuration Services Event Messages (ZDSC)
HP NonStop Operating System Event Management Programming Manual520372-020
24-19
Messages
Cause. $ZCNF received a TNet CRU configured event from the SP for a CRU whose
entry was not found in the Physical CRU Table.
Effect. No entry will be made for this TNet CRU in the TNet node table by $ZCNF and
hence no information about it will be returned.
Recovery. Check for any previous CRU deletion events from the SP. If an event is
found, it means that either SP sent a CRU configured for a CRU that was deleted, or a
CRU insertion event was not received after the CRU was deleted and before CRU was
configured. If no CRU deletion event is found but there is a CRU insertion event,
$ZCNF’s PCT is not updated. In either case, see Recovery Action Requiring Vendor
Support on page 24-10.
1034: ZDSC-EVT-BAD-SEQ-NUMBER
A SP hardware event sequence number that is out of synchronization was received.
Unconditional Tokens
Potentially critical event: No
Action event: No
Message sender: $ZCNF
TMDS collector: No
OSM/TSM collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZDSC-TKN-EXPECTED-SEQ-NUMBER token-type ZSPI-TYP-UINT
ZDSC-TKN-ACTUAL-SEQ-NUMBER token-type ZDSI-TYP-UINT
ZDSC-TKN-SP-DOMAIN-NUMBER token-type ZSPI-TYP-UINT
Event-Message Text
The service processor hardware event sequence number for
cabinet sp-domain-number is out of synchronization with
$ZCNF.
Expected: expected-seq-number
Actual: actual-seq-number
Token Description (page 1 of 2)
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZDSC-
EVT-BAD-SEQ-NUMBER (1034).
ZDSC-TKN-EXPECTED-SEQ-NUMBER Sequence number that $ZCNF expected to
receive. Value is ZDSC-TNM-EXPECTED-SEQ-
NUMBER.