NonStop Operating System Event Management Programming Manual

Complex Manager Auxiliary Process (CMAP) Event
Messages (ZCMP)
HP NonStop Operating System Event Management Programming Manual520372-020
25-45
Messages
Unconditional Tokens
Cause. See Table 25-21.
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZEMS-TKN-EMPHASIS token-type ZSPI-TYP-BOOLEAN
ZEMS-TKN-ISO-SEVERITY token-type ZSPI-TYP-ISO-
SEVERITY
ZCMP-TKN-COMPLEX-ID <1> token-type ZSPI-TYP-INT
ZCPU-TKN-SLICEID <2> token-type ZSPI-TYP-BYTE
ZCPU-TKN-LID <3> token-type ZSPI-TYP-BYTE
ZCPU-TKN-SLICE-TRACKING-ID <4> token-type ZSPI-TYP-STRING
ZCMP-TKN-PE-ISOLATE-ERR <5> token-type ZSPI-TYP-ENUM
Event-Message Text
Unable to isolate LID <3>, in slice <2> of complex <1>
Slice module tracking ID : <4>
Isolate error : <5>
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZCMP-EVT-
PE-ISOLATE-ERROR (123).
ZEMS-TKN-EMPHASIS Value is ZSPI-VAL-FALSE.
ZEMS-TKN-ISO-SEVERITY Value is ZEMS-VAL-SEVERITY-INDETERMIN.
ZCPU-TKN-SLICEID Subject token that specifies the NonStop Blade
Element that contains the PE.
ZCMP-TKN-COMPLEX-ID ID of the affected NonStop Blade Complex.
ZCPU-TKN-SLICEID Subject token that specifies the NonStop Blade
Element that cannot be isolated.
ZCPU-TKN-LID Subject token that specifies the LID of the PE that
cannot be isolated.
ZCPU-TKN-SLICE-TRACKING-ID Tracking ID of the NonStop Blade Element that cannot
be isolated.
ZCMP-TKN-PE-ISOLATE-ERR Reason that PE or NonStop Blade Element cannot be
isolated (seeTable 25-21
).
Table 25-21. ZCMP-TKN-PE-ISOLATE-ERROR Values
Value Meaning
ZCMP-ENM-PEISOLATE-TO Isolation request time limit expired.
ZCMP-ENM-PEISOLATE-ERR Isolation request was rejected.