NonStop Operating System Event Management Programming Manual
Complex Manager Auxiliary Process (CMAP) Event
Messages (ZCMP)
HP NonStop Operating System Event Management Programming Manual—520372-020
25-51
Messages
Effect. If FPGA 3 hardware is not working correctly, PEs that are on the NonStop
Blade Element with the FPGA 3 hardware cannot be reintegrated.
Recovery. Contact your service provider.
127: ZCMP-EVT-TARG-ECHO-INIT-ERROR
Target FPGA 3 hardware could not be initialized.
Unconditional Tokens
Potentially critical event: No
Action event: No
Message sender: CMAP
$ZLOG: Yes
$0: No
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZEMS-TKN-EMPHASIS token-type ZSPI-TYP-BOOLEAN
ZEMS-TKN-ISO-SEVERITY token-type ZSPI-TYP-ISO-
SEVERITY
ZCPU-TKN-LID <1> token-type ZSPI-TYP-BYTE
ZCPU-TKN-SLICEID <2> token-type ZSPI-TYP-BYTE
ZCPU-TKN-SLICE-TRACKING-ID <3> token-type ZSPI-TYP-STRING
ZCMP-TKN-ECHO-CHANNEL <4> token-type ZSPI-TYP-BYTE
ZCMP-TKN-TARG-ECHO-INIT-ERR <5> token-type ZSPI-TYP-ENUM
Event-Message Text
Echo target initialization for PE LID <1> on slice <2> failed
Slice module tracking ID: <3>
Echo Channel : <4>
Echo Initialization failure reason : <5>
Token Description (page1of2)
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZCMP-
EVT-TARG-ECHO-INIT-ERROR (127).
ZEMS-TKN-EMPHASIS Value is ZSPI-VAL-FALSE.
ZEMS-TKN-ISO-SEVERITY Value is ZEMS-VAL-SEVERITY-INDETERMIN.
ZCPU-TKN-LID Subject token that specifies the LID of the
affected PE.
ZCPU-TKN-SLICEID Subject token that specifies the affected
NonStop Blade Element.
ZCPU-TKN-SLICE-TRACKING-ID Tracking ID of the affected NonStop Blade
Element.