NonStop Operating System Event Management Programming Manual
Complex Manager Auxiliary Process (CMAP) Event
Messages (ZCMP)
HP NonStop Operating System Event Management Programming Manual—520372-020
25-73
Messages
206: ZCMP-EVT-COMPLEX-NOW-INVALID
A valid NonStop Blade Complex became invalid.
Unconditional Tokens
Cause. A cabling or hardware error.
Potentially critical event: Yes
Action event: Yes
Message sender: CMAP
$ZLOG: Yes
$0: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZEMS-TKN-EMPHASIS token-type ZSPI-TYP-BOOLEAN
ZEMS-TKN-ISO-SEVERITY token-type ZSPI-TYP-ISO-
SEVERITY
ZCMP-TKN-COMPLEX-ID <1> token-type ZSPI-TYP-INT
ZCPU-TKN-SLICE-TRACKING-ID <2> token-type ZSPI-TYP-STRING
ZCPU-TKN-SLICE-TRACKING-ID1 <3> token-type ZSPI-TYP-STRING
ZCPU-TKN-SLICE-TRACKING-ID2 <4> token-type ZSPI-TYP-STRING
Event-Message Text
Complex ID <1> has been declared invalid
Slice module tracking ID: <2>
Slice module tracking ID1: <3>
Slice module tracking ID2: <4>
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZCMP-
EVT-COMPLEX-NOW-INVALID (206).
ZEMS-TKN-EMPHASIS Value is ZSPI-VAL-TRUE.
ZEMS-TKN-ISO-SEVERITY Value is ZEMS-VAL-SEVERITY-MAJOR.
ZCMP-TKN-COMPLEX-ID NonStop Blade Complex ID of the affected
NonStop Blade Complex.
ZCPU-TKN-SLICE-TRACKING-ID NonStop Blade Element tracking ID of the first
NonStop Blade Element in the NonStop Blade
Complex.
ZCPU-TKN-SLICE-TRACKING-ID1 NonStop Blade Element tracking ID of the
second NonStop Blade Element in the NonStop
Blade Complex.
ZCPU-TKN-SLICE-TRACKING-ID2 NonStop Blade Element tracking ID of the third
NonStop Blade Element in the NonStop Blade