Effect. Events 110, 111, and 112 are hardware errors reported by the Cyclone or
K10000 IPB chip and recorded in a common error counter. If more than 1000 of these
occur in a 19.2-second interval, the operating system shuts down the bus to all
processors and issues the ZIPB-EVT-BUSDOWN (101) event message.
Recovery. Normally, no recovery action is necessary. If the error continues to occur,
see Recovery Action Requiring Vendor Support on page 4-6.
111: ZIPB-EVT-IPBSENDERROR
An error occurred in the send hardware of the IPB interface in a Cyclone or K10000
processor.
Unconditional Tokens
Cause. The IPB interface on the specified processor encountered an error in one of its
send state machines.
Subject: ZIPB-TKN-BUS
Potentially critical event: No
Action event: No
Message sender: Monitor process
TMDS collector: Yes
Unconditional Tokens
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT
ZIPB-TKN-BUS token-type ZSPI-TYP-BYTE
ZIPB-TKN-CPU token-type ZSPI-TYP-UINT
ZIPB-TKN-RPTCPU token-type ZSPI-TYP-UINT
ZIPB-TKN-IPBSENDERRORS token-type ZSPI-TYP-UINT
Event-Message Text
CPU nn : BUS {X|Y} : nn ERRORS IN SEND HARDWARE IN IPB
CONTROLLER.
Token Description
ZEMS-TKN-EVENTNUMBER Event number for this message. Value is ZIPB-EVT-
IPBSENDERROR (111).
ZIPB-TKN-BUS Is the subject token that specifies the bus. Value is either 0
(X bus) or 1 (Y bus).
ZIPB-TKN-CPU Processor number of the processor that reported the error.
ZIPB-TKN-RPTCPU Processor number of the processor where the send errors
occurred (same as ZIPB-TKN-CPU).
ZIPB-TKN-IPBSENDERRORS Number of times the IPB interface reported send hardware
errors.